logo
Thuis > producten > Ion Chromatography Instrument >
IC6600 Ion Chromatography Instrument With Reagent-free Eluent Generator

IC6600 Ion Chromatography Instrument With Reagent-free Eluent Generator

Place of Origin:

Anhui, China

Merknaam:

Wayeal

Certificering:

CE

Model Number:

IC6600

Neem contact met ons op
Vraag een offerte
Productgegevens
De stabiliteit van het stroomtarief:
<0,1%
Eluentconcentratiebereik:
KOH、MSA-0,1 ∙100,0 mm
Stroomstroominstellingstroom:
<0,1%
Pompdruk:
0~42Mpa
Kolomcapaciteit:
2 stuks, 250mm en 150mm
Injectievolume:
10 μl tot en met 4000 μl
Kwantitatieve Herhaalbaarheid:
≤0,5%
Stroomsnelheidsbereik:
0,001~12,000 ml/min
Betaling en verzendvoorwaarden
Minimum Order Quantity
1 Unit
Prijs
Negotiate
Packaging Details
Wooden Case
Delivery Time
35 days
Payment Terms
T/T
Supply Ability
30 Units/Month
Productbeschrijving

Introduction of IC6600 Ion Chromatography Instrument

The IC6600 multi-functional ion chromatograph features an innovative modular design, offering flexible configurations and powerful capabilities. Equipped with an all-PEEK pump head, it is resistant to acids, bases, and reversed-phase organic solvents, thereby preventing metal contamination. Additionally, the system can be flexibly configured with conductivity detectors, amperometric detectors, or UV detectors to meet a wide range of user detection needs.

Technical Parameters of IC6600 Ion Chromatography Instrument

Product Name Multifunctional Ion Chromatography
Model IC6600
Working power 220V, 50Hz
Ambient temperature 10-40°C
Relative humidity 20-85%
Qualitative repeatability ≤0.1%
Quantitative repeatability ≤0.5%
Pump flow rate range 0.001~12.000mL/min
Pressure resistance of pump head 0-40MPa
Flow setting error <0.1%
Flow stability <0.1%
Pressure display accuracy 0.001MPa
Pressure plusation <0.25%
Conductivity detector  
Baseline noise ≤0.03%FS
Baseline drift ≤0.1%FS
Mini detectable concentration (Cl): ≤0.0001μg/mL
Mini detectable concentration (Li): ≤0.00005μg/mL
Mini detectable concentration (NO3): ≤0.001μg/mL
Mini detectable concentration (Na+): ≤0.001μg/mL
Mini detectable concentration (Ca2+): ≤0.005μg/mL
Conductivity cell volume ≤0.4μL
Conductivity detection range 0-45000μS/cm
Detector resolution 0.00238nS/cm
Conductivity cell temperature setting error ±0.01°C
Conductivity cell temperature display resolution 0.001°C
Conductivity cell temperature control range Detector temperature zone temperature +5°C-65°C
Conductivity cell temperature control stability 0.05°C
Conductivity cell temperature setting value error 0.1°C/h
Ampere detector  
Type Thin-layer structure, automatic range
Driving voltage range -2.0V-2.0V
Drive voltage resolution 0.001V
Output signal range

Integral mode: 50pc-200uC

DC mode: 1pA-74μA

Noise

Integration mode<30pC

DC mode<5pA, DC mode static noise<1pA

Cell material Titanium
Pool volume <0.2μL
Maximum pool pressure 0.7MPa
Minimum detectable concerntration I-0.001μg/mL
Minimum detectable concerntration fructose 0.01μg/mL
UV Detector  
Wavelength indication error 0.1nm
Wavelength repeatability 0.1nm
Mini detectable concentration BrO3-0.0005μg/mL
Mini detectable concentration CrO42-0.001μg/mL
Qualitative repeatability ≤0.05%
Quantitative repeatability ≤0.3%
Suppressor  
Dead volume 50μL
Inhibition capacity 170ueq/min
Pressure resistance 3MPa
Column oven  
Temperature range Room temperature +5°C~70°C
Temperature control stability 0.1°C/h
Error of temperature setting value 0.05°C
Autosampler  
Number of samples ≥120 (1.5ml sample bottle)
Temperature 4~30°C
Linear >0.999
Cross-contamination <0.01%

 

Stuur uw vraag rechtstreeks naar ons